Epson Parallel Scanner Cable Diagrams:

These diagrams were copied from the ImageFX Manual from Nova Design. Nova Design includes this disclaimer:

Nova Design Inc, provides this information as a service to the user community. Nova Design assumes no responsibility for damage to equipment resulting from incorrect use of this information.

GVP-Specified Cable Connections: ASDG Specified Cable Connections:
DB24 Male Centronics 36 Male Pin Signal Pin Signal 2 D0 2 D0 3 D1 3 D1 4 D2 4 D2 5 D3 5 D3 6 D4 6 D4 7 D5 5 D5 8 D6 8 D6 9 D7 9 D7 10 ACK* 10 ACKNLG* 11 BUSY 11 BUSY 12 POUT 36 DIR 13 SEL 1 STROBE* 16 Reset* 31 INIT* 22 GND 30 GND 25 GND 33 GND
DB24 Male Centronics 36 Male Pin Signal Pin Signal 1 STROBE* NC NC 2 D0 5 D3 3 D1 8 D6 4 D2 7 D5 5 D3 4 D2 6 D4 2 D0 7 D5 9 D7 8 D6 3 D1 9 D7 6 D4 10 ACK* 10 ACKNLG* 11 BUSY 11 BUSY 12 POUT 1 STROBE* 13 SEL 36 DIR 14 +5V 14 NC 15 NC 32 NC 16 Reset* 31 INIT* 17 GND NC NC